Forced Ventilation Design
The OCM system: window opening/closing – operates with and without electricity.
- with 230 V, it receives 0-10 V commands and opens/closes the windows within the configured travel limits, creating the appropriate airflow for farm ventilation
- Temperature control without 230 V for up to 24 hours: lifting motors with built-in batteries provide autonomy to move the air inlets without electricity. When 230 V power is lost, the OCM system receives commands from the temperature sensor and opens/closes the windows within the configured travel limits, controlling the temperature through natural ventilation.
- 3 types of commands: 0-10 V analogue input for commands from the forced ventilation system; on/off relay input for connecting an external device; temperature sensor input for temperature control for up to 24 hours without 230 V / 0-10 V
Standard Tunnel Forced Ventilation
2 OCM Systems
2 Window Lines*
“The key to success: configure and optimise your equipment.”

Components
- 2 OCM controllers
- 2 lifting motors
- 2 OFA power supplies
- 2 digital temperature sensors
Wiring Diagrams
*The installation diagram is approximate. Component locations depend on the requirements of each project.
Transversal Forced Ventilation
1 OCM System
1 Window Line*
“Every connection brings you closer to an outstanding result.”

Components
- 1 OCM controller
- 1 lifting motor
- 1 OFA power supply
- 1 digital temperature sensor
Wiring Diagrams
*The installation diagram is approximate. Component locations depend on the requirements of each project.
Complete Tunnel Forced Ventilation
2 OCM Systems
2 Window Lines*
1 OCV2 System
2 Window Lines*
“Precision in every detail makes the difference.”

Components
- 2 OCM controllers
- 2 lifting motors
- 2 OFA power supplies
- 2 digital temperature sensors
Wiring Diagrams
Components
- 1 OCV2 controller
- 2 lifting motors
- 2 digital temperature sensors
Wiring Diagrams
*The installation diagram is approximate. Component locations depend on the requirements of each project.
More Diagrams
You can review other ventilation designs for livestock facilities.

Passive ventilation with air circulation and renewal without mechanical support.

Natural Ventilation WITHOUT 230 V
For organic projects powered by a generator set or solar panels.

Immediate-response emergency system in the event of power outages.