OCV3
REF. 4C22050 multiprogram version
- Natural Ventilation.
- Forced Ventilation.
- 3 motors!

Products > Controllers > OCV3 V1 for indoor use
About the product
“Triple control, cutting-edge technology”
OCV3 Version 1 Window Regulator
Electronic device designed to open or close air inlets / windows / dampers, etc.
Manages 3 OSMO lift motors.
Digital temperature probe included (1 per motor).
Motor 3 recommended for chimneys or ridge vents.
Multiprogram microcontroller (since July 2024).
Able to adapt to different types of installations.
Natural ventilation (With our digital temperature probe)
Temperature control from 0ºC to 85ºC with 1ºC hysteresis.
Easy programming and reading of limit switches and control and operating parameters: temperature, battery voltage, window position, maximum opening and minimum closing, etc.
Fault detection system and parameter storage during power outages.
Programmable thermal jump detection (recommendation: NOT LESS THAN 2º).
– Motor 1 and 2: emergency priority command: programmable window positioning with an external device and our auxiliary input.
In the absence of 230 V: we take control by temperature.
– Motor 3: recommended for chimneys or ridge vents.
In the absence of 230 V: two options, take control by temperature or emergency opening
Forced ventilation (in addition to the previous operation):
Motor 1 and 2:
– By adding our CVA* accessory (DP3 PROGRAM) and using the digital temperature probes already installed in our regulator, we activate the connection and disconnection of external devices for: ventilation, cooling, heating, or any type of device.
– Programmable emergency temperature.
Motor 3:
– Different operating possibilities. In the absence of 230 V, two options: take control by temperature or emergency opening.
Technical Data
- Complies with IP56 protection rating requirements
- 12V / 230V
- Dimensions length / width / height: 350 x 163 x 260 mm
- Weight: 3.20 kg
Program Versions
– Motor 1, 2 and 3
- BASIC SINGLE STEP 1.2 cm per step for opening and closing: (version prior to the multiprogram: fixed 2ºC thermal jump, emergency input for the priority opening command activated by an external device).
- DP DOUBLE STEP 2.4 cm per step for opening and closing.
- DP1 (version prior to the multiprogram: with programmable thermal jump, emergency input for the priority opening or closing command (programmable) activated by an external device).
- DP2 with DP1 functions + Temperature band: minimum and maximum temperature programming
– Motor 1 and 2 only
- DP3 with DP1 functions + Heating and ventilation control through the CVA control box *
- DP4 with DP1 functions + Wind control through the CVA control box and anemometer *
- Since 01/07/2024, only MULTIPROGRAM microcontrollers including all versions are available.
- Unified Multiprogram Microcontroller with all programming versions
- Unified Multiprogram Microcontroller APP for remote management of OSMO equipment
Documentation and manuals
Instructions
OCV3 Multiprogram Version
ESP. OCV3 MP Rev. 3 dated 01/01/2026
OCM Micro Version: 032
OCV2 Micro Version: 031




Wiring and Installation
OCV3 Multiprogram Version
ESP. OCV3 CI MP Rev. 3 dated 01/01/2026


Instructions
OCV3 Multiprogram Version
ESP. OCV3 MP Rev. 0 dated 01/01/2024
OCM Micro Version < 032
OCV2 Micro Version < 031




Wiring and Installation
OCV3 Multiprogram Version
ESP. OCV3 CI MP Rev. 0 dated 01/01/2024


Instructions
OCV3 Basic Version
ESP. OCV3 B Rev. 0 dated 22/06/2021
Wiring and installation
OCV3 Basic Version
ESP. OCV3 CI Rev. 0 dated 23/06/2021
Instructions
OCV3 DP1
ESP. OCV3 DP1 Rev. 0 dated 16/05/2022
Instructions
OCV3 DP2
ESP. OCV3 DP2 Rev. 0 dated 16/05/2022
Instructions
OCV3 DP3
ESP. OCV3 DP3 Rev. 0 dated 18/05/2022
Instructions
OCV3 DP4
ESP. OCV3 DP4 Rev. 0 dated 16/05/2022
Common faults
OCV3 Faults and Solutions
ESP. OCV3 Faults Rev. 0 dated 22/06/2021
Connection Diagrams
Connection Diagram
Systems with the OCV3 regulator
Installation Diagrams
Below we show standard diagrams for the different installations. The location of the elements is approximate and may vary depending on the actual requirements of each project.

Regulators compatibles con sistemas de ventiladores

Passive ventilation with air circulation and renewal without mechanical assistance.

Natural Ventilation WITHOUT 230 V
For organic projects powered by a generator set or solar panels.

Immediate-response emergency system in the event of power outages.