15 Nov Sudden changes in temperature? Solutions!
SUDDEN CHANGES IN TEMPERATURE?
Everything is under control!
OCV2 regulator
Natural ventilation by temperature for 1-2 motors
OCV3 regulator
Natural ventilation by temperature for 1-3 motors
OCM regulator
Natural ventilation by temperature / Forced ventilation
for 1 motor
OSMO natural ventilation systems
control the programmed temperature with a hysteresis of 1Cº as well as protect animals from sudden temperature change
Sudden temperature drop
for closing windows: programmable, equal to or greater than 2ºC
How does it work?
If there has been a sudden drop in temperature,
air inlets close
to the middle of the open position continuously, they wait 4 minutes, and if the digital temperature probe does not indicate an improvement in temperature, they close to the middle of the position that has remained open continuously again and wait for others 4 minutes.
The process is repeated until the required temperature is established or the air inlets are completely closed.
Auxiliary input (relay On/Off)
for priority closing or opening
How does it work?
If there is a sudden rise or fall in temperature
which requires extraordinary measures,
whatever the programmed automatic mode,
a connected thermostat
will have priority for the closing or opening the air inlets (with programmable limits)
By the way!
OSMO EMERGENCY system also has this advantage
How does it work?
Although its main function is anti suffocation when the 230 V disappear,
if it’s too hot or too cold outside, air inlets can be prevented from closing or opening
OSMO EMERGENCY SYSTEM
IS THE MOST COMPLETE IN THE MARKET