The manual pushbuttons in the motor

The manual pushbuttons in the motor

Inside every OSMO motor
or External Battery Box,
there is a manual control circuit
with the UP and DOWN pushbuttons,
which are able to move the motor
regardless of regulator

¡IMPORTANT!

THEY MUST BE USED ONLY IN CASE OF BREAKDOWN
WHICH PREVENTS THE REGULATOR CONTROLLING THE MOTOR

DO NOT USE

the push buttons of the manual control circuit
to move the motor
WHILE THE REGULATOR IS IN AUTOMATIC MODE
and working properly.
If you do, the centimeters of the towrope that the motor has wound up will have varied,
and the regulator will NOT have detected them,
which will cause the loss of the limit switch
and, consequently, a serious failure due to this desynchronization.

ONLY TO BE USED

when the failure of the regulator blocks the system
and the problem can’t be solved through the regulator.

IT IS OBLIGATORY TO REPROGRAMME THE REGULATOR

after having used the pushbuttons of the manual control circuit, establishing again the limits of the maximum and minimum air inlet initial travel.

THE CORRECT USE AND MAINTENANCE
OF THE EQUIPMENT
WILL GUARANTEE THE SAFETY
OF THE FACILITIES AND THE ANIMALS