16 Jun Conexiones de equipos ¡Así no se hace!
WE REMIND YOU ABOUT
4 MAIN RULES
TO GUARANTEE
THE RIGHT CONNECTION
OF OSMO EQUIPMENT
-
1.
It is obligatory to use multiconductor flexible sheath
NEVER use separate conductors
2.
DO NOT pass the multiconductor sheath near heat sources
3.
DO NOT SHARE tube or channel protection of multiconductor sheathesconnecting OSMOEUROPA
equipment with other multiconductor sheathes carrying energy (230 V / 400 V)
4.
Avoid extending the multi-conductor sheath by joining several wires together,
since they have a risk of moisture penetration that can cause damage to the equipment.
If this extension is unavoidable, use connection terminals mounted individually or in connection blocks or strips and always inside connection boxes except when they are inside a protective channel
IMPORTANT:
– Turn off the regulator before making any connection and disconnection.
Remember that before turning off the regulator,
it must be switched to MANUAL mode to avoid losing steps while the motor is moving
– The cables that OSMOEUROPA uses for equipment are standardized with the indicated wires and thickness