09 Mar Correct maintenance of batteries for DC motors
COMPLIANCE WITH THE NORMS GUARANTEES PROPER FUNCTIONING DURABILITY SAFETY OF ANIMALS AND FACILITIES |
|
If the batteries do not have an adequate charge, it is very possible that the regulator begins to show signs of failure in the motor (blockage, loss of steps, etc.)
A battery has an average life of 2 years, as long as its maintenance
has been appropriate.
To ensure correct operation, check the internal batteries annually
HOW TO CHECK THE BATTERIESTHE MOTOR:
-Using the OSMO regulator close the air inlets completely
-Disconnect the OSMO regulator from the power source (230 V electrical network, generator set or solar panel)
-Change its operation to MANUAL model
-Using the regulator open and close the air inlets completely 1 time.
If the process of opening and closing the air inlets has been fluent and the motor has not shown signs of loss of power, the batteries are in good condition. |
If the process of opening and closing the air inlets has been interrupted and the motor has shown signs of loss of power, the batteries need to be changed and the regulator corresponding to the motor will show the indicators of blockage. |
What to do? 1.Reconnect the regulator to the power source. 2.Change its operation to Automatic mode No need to reprogramme it again. |
What to do? Change the batteries. 2.Reconnect the regulator to the power source and reset the regulator. 3.Reprogramme the initial limit switches again |